Back to Wsl2 Linux Kernel

Kernel driver max34440

Documentation/hwmon/max34440.rst

5.5.36.1 KB
Original Source

Kernel driver max34440

Supported chips:

Author: Guenter Roeck [email protected]

Description

This driver supports hardware monitoring for Maxim MAX34440 PMBus 6-Channel Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger. It also supports the MAX34451, MAX34460, and MAX34461 PMBus Voltage Monitor & Sequencers. The MAX34451 supports monitoring voltage or current of 12 channels based on GIN pins. The MAX34460 supports 12 voltage channels, and the MAX34461 supports 16 voltage channels.

The driver is a client driver to the core PMBus driver. Please see Documentation/hwmon/pmbus.rst for details on PMBus client drivers.

Usage Notes

This driver does not auto-detect devices. You will have to instantiate the devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for details.

For MAX34446, the value of the currX_crit attribute determines if current or voltage measurement is enabled for a given channel. Voltage measurement is enabled if currX_crit is set to 0; current measurement is enabled if the attribute is set to a positive value. Power measurement is only enabled if channel 1 (3) is configured for voltage measurement, and channel 2 (4) is configured for current measurement.

Platform data support

The driver supports standard PMBus driver platform data.

Sysfs entries

The following attributes are supported. Limits are read-write; all other attributes are read-only.

In ~~

======================= ======================================================= in[1-6]_label "vout[1-6]". in[1-6]_input Measured voltage. From READ_VOUT register. in[1-6]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register. in[1-6]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. in[1-6]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register. in[1-6]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. in[1-6]_lowest Historical minimum voltage. in[1-6]_highest Historical maximum voltage. in[1-6]_reset_history Write any value to reset history. ======================= =======================================================

.. note:: MAX34446 only supports in[1-4].

Curr


======================= ========================================================
curr[1-6]_label		"iout[1-6]".
curr[1-6]_input		Measured current. From READ_IOUT register.
curr[1-6]_max		Maximum current. From IOUT_OC_WARN_LIMIT register.
curr[1-6]_crit		Critical maximum current. From IOUT_OC_FAULT_LIMIT
			register.
curr[1-6]_max_alarm	Current high alarm. From IOUT_OC_WARNING status.
curr[1-6]_crit_alarm	Current critical high alarm. From IOUT_OC_FAULT status.
curr[1-4]_average	Historical average current (MAX34446/34451 only).
curr[1-6]_highest	Historical maximum current.
curr[1-6]_reset_history	Write any value to reset history.
======================= ========================================================

.. note::

    - in6 and curr6 attributes only exist for MAX34440.
    - MAX34446 only supports curr[1-4].

Power

======================= ======================================================== power[1,3]_label "pout[1,3]" power[1,3]_input Measured power. power[1,3]_average Historical average power. power[1,3]_highest Historical maximum power. ======================= ========================================================

.. note:: Power attributes only exist for MAX34446.

Temp


======================= ========================================================
temp[1-8]_input		Measured temperatures. From READ_TEMPERATURE_1 register.
			temp1 is the chip's internal temperature. temp2..temp5
			are remote I2C temperature sensors. For MAX34441, temp6
			is a remote thermal-diode sensor. For MAX34440, temp6..8
			are remote I2C temperature sensors.
temp[1-8]_max		Maximum temperature. From OT_WARN_LIMIT register.
temp[1-8]_crit		Critical high temperature. From OT_FAULT_LIMIT register.
temp[1-8]_max_alarm	Temperature high alarm.
temp[1-8]_crit_alarm	Temperature critical high alarm.
temp[1-8]_average	Historical average temperature (MAX34446 only).
temp[1-8]_highest	Historical maximum temperature.
temp[1-8]_reset_history	Write any value to reset history.
======================= ========================================================


.. note::
   - temp7 and temp8 attributes only exist for MAX34440.
   - MAX34446 only supports temp[1-3].


.. note::

   - MAX34451 supports attribute groups in[1-16] (or curr[1-16] based on
     input pins) and temp[1-5].
   - MAX34460 supports attribute groups in[1-12] and temp[1-5].
   - MAX34461 supports attribute groups in[1-16] and temp[1-5].