Documentation/tools/rtla/common_osnoise_options.rst
-a, --auto us
Set the automatic trace mode. This mode sets some commonly used options
while debugging the system. It is equivalent to use **-s** *us* **-T 1 -t**.
-p, --period us
Set the *osnoise* tracer period in microseconds.
-r, --runtime us
Set the *osnoise* tracer runtime in microseconds.
-s, --stop us
Stop the trace if a single sample is higher than the argument in microseconds.
If **-T** is set, it will also save the trace to the output.
-S, --stop-total us
Stop the trace if the total sample is higher than the argument in microseconds.
If **-T** is set, it will also save the trace to the output.
-T, --threshold us
Specify the minimum delta between two time reads to be considered noise.
The default threshold is *5 us*.
-t, --trace [file]
Save the stopped trace to [*file|osnoise_trace.txt*].