-a, --auto us

    Set the automatic trace mode. This mode sets some commonly used options
    while debugging the system. It is equivalent to use **-s** *us* **-T 1 -t**.

-p, --period us

    Set the *osnoise* tracer period in microseconds.

-r, --runtime us

    Set the *osnoise* tracer runtime in microseconds.

-s, --stop us

    Stop the trace if a single sample is higher than the argument in microseconds.
    If **-T** is set, it will also save the trace to the output.

-S, --stop-total us

    Stop the trace if the total sample is higher than the argument in microseconds.
    If **-T** is set, it will also save the trace to the output.

-T, --threshold us

    Specify the minimum delta between two time reads to be considered noise.
    The default threshold is *5 us*.

-t, --trace [file]

    Save the stopped trace to [*file|osnoise_trace.txt*].