scientific-skills/iso-13485-certification/SKILL.md
This skill helps medical device manufacturers prepare comprehensive documentation for ISO 13485:2016 certification. It provides tools, templates, references, and guidance to create, review, and gap-analyze all required Quality Management System (QMS) documentation.
What this skill provides:
When to use this skill:
When to start here: User has existing documentation and needs to identify gaps
Process:
Collect existing documentation:
Run gap analysis script:
python scripts/gap_analyzer.py --docs-dir <path_to_docs> --output gap-report.json
Review results:
Present findings to user:
Output: Comprehensive gap analysis report with prioritized action items
When to use: User needs to understand specific ISO 13485 requirements
Available references:
references/iso-13485-requirements.md - Complete clause-by-clause breakdownreferences/mandatory-documents.md - All 31 required procedures explainedreferences/gap-analysis-checklist.md - Detailed compliance checklistreferences/quality-manual-guide.md - How to create Quality ManualHow to use:
For specific clause questions:
iso-13485-requirements.mdFor document requirements:
mandatory-documents.mdFor implementation guidance:
quality-manual-guide.md for policy-level documentsKey reference sections to know:
When to use: User needs to create specific QMS documents
Available templates:
assets/templates/quality-manual-template.mdassets/templates/procedures/CAPA-procedure-template.mdassets/templates/procedures/document-control-procedure-template.mdProcess for document creation:
Identify what needs to be created:
Select appropriate template:
Customize template with user-specific information:
Key customization areas:
Validate completeness:
Document creation priority order:
Phase 1 - Foundation (Critical):
Phase 2 - Core Processes (High Priority): 5. Corrective and Preventive Action (CAPA) 6. Complaint Handling 7. Internal Audit 8. Management Review 9. Risk Management
Phase 3 - Product Realization (High Priority): 10. Design and Development (if applicable) 11. Purchasing 12. Production and Service Provision 13. Control of Nonconforming Product
Phase 4 - Supporting Processes (Medium Priority): 14. Training and Competence 15. Calibration/Control of M&M Equipment 16. Process Validation 17. Product Identification and Traceability
Phase 5 - Additional Requirements (Medium Priority): 18. Feedback and Post-Market Surveillance 19. Regulatory Reporting 20. Customer Communication 21. Data Analysis
Phase 6 - Specialized (If Applicable): 22. Installation (if applicable) 23. Servicing (if applicable) 24. Sterilization (if applicable) 25. Contamination Control (if applicable)
Process:
Read the comprehensive guide:
references/quality-manual-guide.md in fullGather organization information:
Use template:
assets/templates/quality-manual-template.mdComplete required sections:
Key requirements:
Validation checklist:
General approach for all procedures:
Understand the requirement:
references/iso-13485-requirements.mdUse template structure:
Define responsibilities clearly:
Document the "what" not excessive "how":
Include required elements:
Example: Creating CAPA Procedure
assets/templates/procedures/CAPA-procedure-template.mdWhat is an MDF:
Required contents per ISO 13485 Clause 4.2.3:
Process:
When to use: User wants detailed assessment of all requirements
Process:
Use comprehensive checklist:
references/gap-analysis-checklist.mdFor each clause:
Summarize by clause:
Create action plan:
Output:
User request: "We're a medical device startup and need to implement ISO 13485. Where do we start?"
Approach:
Explain the journey:
Start with foundation:
Follow the priority order:
Key milestones:
User request: "We have some procedures but don't know what we're missing for ISO 13485."
Approach:
Run automated gap analysis:
scripts/gap_analyzer.pyConduct detailed assessment:
Provide prioritized gap list:
Create remediation plan:
User request: "Help me create a CAPA procedure."
Approach:
Explain requirements:
Use template:
Gather user-specific info:
Create customized procedure:
Add supporting materials:
User request: "We need to update our QMS for FDA QMSR harmonization."
Approach:
Explain changes:
Review current documentation:
Update strategy:
Create transition plan:
User request: "We have our documentation ready. How do we prepare for the certification audit?"
Approach:
Conduct readiness assessment:
Pre-audit checklist:
Conduct mock audit:
Address findings:
Final preparation:
Start at policy level, then add detail:
Maintain consistency:
Write for your audience:
Make procedures usable:
When you can exclude:
Justification requirements:
Example good justification:
"Clause 7.3 Design and Development is excluded. ABC Company operates as a contract manufacturer and produces medical devices according to complete design specifications provided by customers. All design activities are performed by the customer and ABC Company has no responsibility for design inputs, outputs, verification, validation, or design changes."
Example poor justification:
"We don't do design." (Too brief, doesn't explain why or demonstrate no impact)
Copying ISO 13485 text verbatim
Making procedures too detailed
Creating documents in isolation
Forgetting records
Inadequate approval
gap_analyzer.py - Automated tool to analyze existing documentation and identify gaps against ISO 13485 requirementsiso-13485-requirements.md - Complete breakdown of ISO 13485:2016 requirements clause by clausemandatory-documents.md - Detailed list of all 31 required procedures plus other mandatory documentsgap-analysis-checklist.md - Comprehensive checklist for detailed gap assessmentquality-manual-guide.md - Step-by-step guide for creating a compliant Quality Manualquality-manual-template.md - Complete template for Quality Manual with all required sectionsprocedures/CAPA-procedure-template.md - Example CAPA procedure following best practicesprocedures/document-control-procedure-template.md - Example document control procedure(Note: Traditional count is "31 procedures" though list shows more because some are conditional)
FDA (United States):
EU (European Union):
Canada:
Other Regions:
Minimum retention: Lifetime of medical device as defined by organization
Typical retention periods:
Always comply with applicable regulatory requirements which may specify longer periods.
First-time users should:
references/iso-13485-requirements.md to understand the standardFor specific tasks:
Need help? Start by describing your situation: what stage you're at, what you have, and what you need to create.