This document is listing all the static-analysis checks that are performed on the Airbyte connectors. These checks are running in our CI/CD pipeline and are used to ensure a connector is following the best practices and is respecting the Airbyte standards. Meeting these standards means that the connector will be able to be safely integrated into the Airbyte platform and released to registries (DockerHub, Pypi etc.). You can consider these checks as a set of guidelines to follow when developing a connector. They are by no mean replacing the need for a manual review of the connector codebase and the implementation of good test suites.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with 100 internal support level Applies to connector with any Airbyte usage level
When a breaking change is introduced, we check that a migration guide is available. It should be stored under ./docs/integrations/<connector-type>s/<connector-name>-migrations.md.
This document should contain a section for each breaking change, in order of the version descending. It must explain users which action to take to migrate to the new version.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with 100 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should be stored under ./docs/integrations/<connector-type>s/<connector-name>.md.
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should update invalid links in connector documentation. For links that are used as example and return 404 status code, use example: before link to skip it.
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
This check expects the following order of headers in the documentation:
# CONNECTOR_NAME_FROM_METADATA
## Prerequisites
## Setup guide
## Set up CONNECTOR_NAME_FROM_METADATA
### For Airbyte Cloud:
### For Airbyte Open Source:
### CONNECTOR_SPECIFIC_FEATURES
## Set up the CONNECTOR_NAME_FROM_METADATA connector in Airbyte
### For Airbyte Cloud:
### For Airbyte Open Source:
## CONNECTOR_SPECIFIC_FEATURES
## Supported sync modes
## Supported Streams
## CONNECTOR_SPECIFIC_FEATURES
### Performance considerations
## Data type map
## Limitations & Troubleshooting
### CONNECTOR_SPECIFIC_FEATURES
### Tutorials
## Changelog
List of not required headers, which can be not exist in the documentation and their strict check will be skipped:
Set up the CONNECTOR_NAME_FROM_METADATA connector in Airbyte
For Airbyte Cloud: (as subtitle of Set up CONNECTOR_NAME_FROM_METADATA)
For Airbyte Open Source: (as subtitle of Set up CONNECTOR_NAME_FROM_METADATA)
CONNECTOR_SPECIFIC_FEATURES (but this headers should be on a right place according to expected order)
Performance considerations
Data type map
Limitations & Troubleshooting
Tutorials
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should update Prerequisites section with description for all required fields from source specification. Having described all required fields in a one place helps Airbyte users easily set up the source connector.
If spec has required credentials/access_token/refresh_token etc, check searches for one of ["account", "auth", "credentials", "access", "client"] words. No need to add credentials/access_token/refresh_token etc to the section
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
Check verifies that CONNECTOR_NAME_FROM_METADATA header section content follows standard template:
<HideInUI>
This page contains the setup guide and reference information for the [CONNECTOR_NAME_FROM_METADATA]({docs_link}) source connector.
</HideInUI>
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
Check verifies that For Airbyte Cloud: header section content follows standard template:
1. [Log into your Airbyte Cloud](https://cloud.airbyte.com/workspaces) account.
2. Click Sources and then click + New source.
3. On the Set up the source page, select CONNECTOR_NAME_FROM_METADATA from the Source type dropdown.
4. Enter a name for the CONNECTOR_NAME_FROM_METADATA connector.
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
Check verifies that For Airbyte Open Source: header section content follows standard template:
1. Navigate to the Airbyte Open Source dashboard.
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
Check verifies that Supported sync modes header section content follows standard template:
The CONNECTOR_NAME_FROM_METADATA source connector supports the following [sync modes](https://docs.airbyte.com/cloud/core-concepts/#connection-sync-modes):
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
Check verifies that Tutorials header section content follows standard template:
Now that you have set up the CONNECTOR_NAME_FROM_METADATA source connector, check out the following CONNECTOR_NAME_FROM_METADATA tutorials:
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with 300 internal support level Applies to connector with any Airbyte usage level
The user facing connector documentation should follow the guidelines defined in the standard template.
Check verifies that Changelog header section content follows standard template:
<details>
<summary>Expand to review</summary>
</details>
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with 100 internal support level Applies to connector with any Airbyte usage level
Each new version of a connector must have a changelog entry defined in the user facing documentation in ./docs/integrations/<connector-type>s/<connector-name>.md.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors must have a metadata.yaml file at the root of their directory. This file is used to build our connector registry. Its structure must follow our metadata schema. Field values are also validated. This is to ensure that all connectors have the required metadata fields and that the metadata is valid. More details in this documentation.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors must have a language tag in their metadata. It must be set in the tags field in metadata.yaml. The values can be language:python or language:java. This checks infers the correct language tag based on the presence of certain files in the connector directory.
Applies to the following connector types: source, destination Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Python connectors must have a CDK tag in their metadata. It must be set in the tags field in metadata.yaml. The values can be cdk:low-code, cdk:python, or cdk:file.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
If the connector version has a breaking change, the deadline field must be set to at least a week in the future.
Applies to the following connector types: source Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with certified support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Certified source connectors must have a value filled out for maxSecondsBetweenMessages in metadata. This value represents the maximum number of seconds we could expect between messages for API connectors. And it's used by platform to tune connectors heartbeat timeout. The value must be set in the 'data' field in connector's metadata.yaml file.
Applies to the following connector types: source, destination Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors must use Poetry for dependency management. This is to ensure that all connectors use a dependency management tool which locks dependencies and ensures reproducible installs.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors must be licensed under the MIT or Elv2 license. This is to ensure that all connectors are licensed under a permissive license. More details in our License FAQ.
Applies to the following connector types: source, destination Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors license in metadata.yaml and pyproject.toml file must match. This is to ensure that all connectors are consistently licensed.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connector version must follow the Semantic Versioning scheme. This is to ensure that all connectors follow a consistent versioning scheme. Refer to our Semantic Versioning for Connectors for more details.
Applies to the following connector types: source, destination Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connector version in metadata.yaml and pyproject.toml file must match. This is to ensure that connector release is consistent.
Applies to the following connector types: source Applies to the following connector languages: python, low-code Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Python connectors must have PyPi publishing enabled in their metadata.yaml file. This is declared by setting remoteRegistries.pypi.enabled to true in metadata.yaml. This is to ensure that all connectors can be published to PyPi and can be used in PyAirbyte.
source-declarative-manifest as their base imageApplies to the following connector types: source, destination Applies to the following connector languages: manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Manifest-only connectors must use airbyte/source-declarative-manifest as their base image.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Each connector must have an icon available in at the root of the connector code directory. It must be an SVG file named icon.svg and must be a square.
Applies to the following connector types: source, destination Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors must use HTTPS only when making requests to external services.
Applies to the following connector types: source, destination Applies to the following connector languages: python, low-code, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with any Airbyte usage level
Connectors must use our Python connector base image (docker.io/airbyte/python-connector-base), declared through the connectorBuildOptions.baseImage in their metadata.yaml.
This is to ensure that all connectors use a base image which is maintained and has security updates.
Applies to the following connector types: source Applies to the following connector languages: java, low-code, python, manifest-only Applies to connector with any support level Applies to connector with any internal support level Applies to connector with medium, high Airbyte usage level
Medium to High Use Connectors must enable acceptance tests via the connectorTestSuitesOptions.suite:acceptanceTests in their respective metadata.yaml file to ensure that the connector is working as expected.